DC to DC
STEP UP
DC-DC Converter
• High continuous and intermittent power loads available
• Heavy-duty marine grade construction
• Protection from incorrect connection and application
• Diagnostic LED indicator for simple fault finding
• EMC compatibility for peace of mind
• Two years world wide manufacturers warranty
• Australian designed, engineered and manufactured
The SVC Series switchmode voltage converters from interVOLT
are used specifically to step-down the high 24VDC on-board
power supply to the lower 12VDC range. this is primarily because
12VDC is a more universally accepted voltage and there is a
greater range of accessories and equipment available on the
market. the SVC Series is ideal for operating a multitude of
12VDC items including but not restricted to, radio’s,
sounders, GPs, radar, sonar, instruments, stereo’s, laptop
computers, security systems, lighting, fridges, pumps and much
more. the SVC Series are non-isolated which means they utilise
a common negative between the input and output. Galvanically
isolated versions are also readily available and known as the
SVCi Series. In the majority of applications the non-isolated
version is preferred, generally because they are less expensive
tdan the isolated versions and because the higher specification
of the galvanically isolated model may not be required. |
|
PARAMETER |
SVC241210 |
SVC241220 |
SCV241230 |
SVC241240 |
Continuous Load Rating @ 25°C |
10 Amps |
20 Amps |
30 Amps |
40 Amps |
Intermittent Load Rating @ 25°C * |
15 Amps |
25 Amps |
35 Amps |
45 Amps |
Peak Load Rating @ 25°C ** |
20 Amps |
30 Amps |
40 Amps |
50 Amps |
Input Voltage Range |
17-33 VDC |
Output Voltage |
13.7 VDC nominal (up to the maximum rated load) |
Standby current draw (average) |
25 mA |
Power Conversion Efficiency @ 25°C |
Typically 94% |
Output ripple |
Less tdan 20 mV Peak to Peak |
Operating Temperature |
Ideally -25°C to + 40°C |
Operating Humidity |
Ideally less tdan 90% |
Enclosure material |
Marine grade aluminium dye anodised |
Enclosure End Caps |
Injection moulded electrical grade ABS/PC plastic |
Diagnostic Indicator |
Tri-colour LED (see specification for description) |
Transient Voltage Protection |
Filtering - Purpose designed circuit |
Over Load/Short Circuit Protection |
Shutdown – Current sensing circuit (automatic
reset) |
Input Under Voltage Protection |
Shutdown – Voltage sensing circuit (automatic
reset) |
Over Temperature Protection |
Shutdown – Temperature sensing circuit
(automatic reset) |
Negative Disconnect Protection |
Shutdown – Voltage sensing circuit (automatic
reset) |
Output Over Voltage Protection |
Internal Fuse – Zener crowbar circuit (not
user serviceable) |
Input Reverse Polarity Protection |
Internal Fuse – Diode bypass circuit (not
user serviceable) |
Termination |
Screw Terminal – 10-32 UNC witd 304 SS
Phillips screw |
Conformity |
EMC – Australian AS2064 and European EN50081-1
/ EN50082-1 |
Certification |
EMC – Australian C Tick mark and European
CE mark |
Lengtd Overall |
160mm |
205mm |
235mm |
275mm |
Widtd Overall |
136mm |
136mm |
136mm |
136mm |
Height Overall |
55mm |
55mm |
55mm |
55mm |
Weight |
805 grams |
1040 grams |
1240 grams |
1505 grams |
DC-DC Converter "Isolated"
The SVCi Series switchmode voltage converters from interVOLT
are used specifically to step-down the high 24VDC on-board
power supply to the lower 12VDC range. this is primarily because
12VDC is a more universally accepted voltage and there is a
greater range of accessories and equipment available on the
market. the SVCi Series is ideal for operating a multitude
of 12Vdc items including but not restricted to, radio’s,
sounders, GPS, radar, sonar, instruments, stereo’s, laptop
computers, security systems, lighting, fridges, pumps and much
more. InterVOLT SVCi Series voltage converters utilise push-pull
technology and purpose designed circuitry to stabilize the
output voltage at a pre-determined setting. they are also galvanically
isolated which means the input circuit is completely electrically
isolated from the output circuit. interVOLT converters are
also available in a non-isolated (common negative) version
known as the SVC Series. In the bulk of applications the non-isolated
version is preferred, generally because they are less expensive
tdan the isolated versions and because the higher specification
of the galvanically isolated model is not required. |
|
PARAMETER |
SVCi241215 |
SVCi241225 |
Continuous Load Rating @ 25°C |
15 Amps |
25 Amps |
Intermittent Load Rating @ 25°C * |
20 Amps |
30 Amps |
Peak Load Rating @ 25°C ** |
25 Amps |
35 Amps |
Input Voltage Range |
17-33 VDC |
Output Voltage – Low Setting |
12.5 VDC nominal |
Output Voltage – High Setting |
13.6 VDC nominal |
Standby current draw (average) |
25 mA |
Power Conversion Efficiency @ 25°C |
Typically 92% |
Output ripple |
Less tdan 20 mV Peak to Peak |
Operating Temperature |
Ideally -25°C to + 40°C |
Operating Humidity |
Ideally less tdan 90% |
Enclosure material |
Marine grade aluminium dye anodized |
Enclosure End Caps |
Injection moulded electrical grade ABS/PC plastic |
Diagnostic Indicator |
Tri-colour LED (see specification for description) |
Transient Voltage Protection |
Filtering - Purpose designed circuit |
Over Load/Short Circuit Protection |
Shutdown – Current sensing circuit (automatic
reset) |
Input Under Voltage Protection |
Shutdown – Voltage sensing circuit (automatic
reset) |
Over Temperature Protection |
Shutdown – Temperature sensing circuit
(automatic reset) |
Negative Disconnect Protection |
Shutdown – Voltage sensing circuit (automatic
reset) |
Output Over Voltage Protection |
Shutdown – Purpose designed dual circuits
(manual reset) |
Input Reverse Polarity Protection |
Internal Fuse – Diode bypass circuit (not
user serviceable) |
Termination |
Screw Terminal – 10-32 UNC witd 304 SS
Phillips screw |
Conformity |
EMC – Australian AS2064 and European EN50081-1
/ EN50082-1 |
Certification |
EMC – Australian C Tick mark and European
CE mark |
Lengtd Overall |
205mm |
275mm |
Widtd Overall |
136mm |
136mm |
Height Overall |
55mm |
55mm |
Weight |
1120 grams |
1650 grams |
*Based on a 50% duty cycle at 10 minute intervals
over and above the continuous load rating. ** Based on a surge
current load greater than or equal to 10 seconds. |
Maximizer Series Voltage Reducers - 24VDC to
12VDC Single Circuit Switchmode
Features
- High efficiency switchmode technology allowing cooler
operation and longer life
- Soft-start via control wire
- Manufactured in Australia
Protection
- Input-to-output protection via diode to guard against
reversing of leads
- Current and voltage foldback under overload conditions
- Voltage foldback under short circuit conditions
- Overvoltage protection to safeguard equipment
- thermal protection - unit shuts down under overload and/or
low input battery voltage conditions
- Eartd loss protection - unit shuts down if the eartd
is lost
Construction
- Compact and light weight aluminium heatsink
|
|
Model |
DSC-110 |
DSC-120 |
DSC-130 |
DSC-150 |
Input voltage |
20V-30VDC |
20V-30VDC |
20V-30VDC |
20V-30VDC |
Output voltage |
13.5VDC ± 5% |
13.5VDC ± 5% |
13.5VDC ± 5% |
13.5VDC ± 5% |
Efficiency @ nominal 24VDC input |
93.5% |
83% |
88.5% |
88.5% |
Output current |
10 Amp |
20 Amp |
30 Amp |
50 Amp |
Standby current |
10mA |
20mA |
30mA |
60mA |
Switching frequency |
200 kHz |
200 kHz |
200 kHz |
200 kHz |
RF noise level complies witd AS2064 |
|
|
|
|
Short circuit protection |
|
|
|
|
Input-to-output protection |
|
|
|
|
Current limited |
|
|
|
|
thermal protection |
|
|
|
|
Output connections |
4 fly leads |
4 fly leads |
4 fly leads |
4 fly leads |
Dimensions L x W x H (mm) |
90 x 140 x 60 |
155 x 140 x 60 |
220 x 140 x 60 |
440 x 140 x 60 |
Weight |
0.74 kg |
1.2 kg |
1.6 kg |
2.76 kg |
Warranty |
2 years |
2 years |
2 yearsdsc- |
2 years |
100W-150W single output DC-DC converter
features
- 2:1 wide input range
- 1500 VAC I/O isolation
- Built in EMI Filter, low ripple noise
Protections:
- Short circuit/overload/overvoltage
- High reliability/ Low cost
- 100% full load burning test
DC Adjust range.....................5V:4.5-5.5V, 12V:11-16V,
24V:23-30V
Line Regulation...............................±0.5%
(Max)
Load regulation...............................±0.5%
(Max)
Overload protection.........................105%-135% hiccup
mode, auto recovery
Over volt protection........................115%-165% of rated
output voltage
Witdstand Voltage ..........................I/P-O/P :1.5KV,
I/P-fg 1.5KV, 1min.
Isolation resistance...........................100M ohm (min)
@500V DC
Working temp. ...................................-10degC to
+60deg C
Safety standards................................24V and 48V
meet LVD
EMC Standards ................................... EN 550022
class B, EN61000-4-2,3,4,6,8 |
|
Model no |
Input |
Output |
R and N |
Efficiency % |
P.P. |
SD-100B-5 |
19-36V |
5V 20A |
100mV |
74 |
81 |
SD-100B-12 |
19-36V |
12V 8.5A |
120mV |
75 |
81 |
SD-100B-24 |
19-36V |
24V 4.2A |
150mV |
78 |
81 |
SD-100C-5 |
36-72V |
5V 20A |
100mV |
75 |
81 |
SD-100C-12 |
36-72V |
12V 8.5A |
120mV |
77 |
81 |
SD-100C-24 |
36-72V |
24V 4.2A |
150mV |
81 |
81 |
SD-100D-5 |
72-144V |
5V 20A |
100mV |
76 |
81 |
SD-100D-12 |
72-144V |
12V 8.5A |
120mV |
80 |
81 |
SD-100D-24 |
72-144V |
24V 4.2A |
150mV |
83 |
81 |
SD-150B-12 |
19-36V |
12V 12.5A |
120mV |
75 |
100 |
SD-150B-24 |
19-36V |
24V 6.3A |
150mV |
77 |
100 |
SD-150C-12 |
36-72V |
12V 12.5A |
120mV |
77 |
100 |
SD-150C-24 |
36-72V |
24V 6.3A |
150mV |
80 |
100 |
SD-150D-12 |
72-144V |
12V 12.5A |
120mV |
79 |
100 |
SD-150D-24 |
72-144V |
24V 6.3A |
150mV |
82 |
100 |
25APK Series DC/DC Single output 25-60 Watts Isolated
Features
- Input voltage optionss 12VDC 24VDC and 48 VDC
- Low profile fully encapsulated model
- ideal for harsh environments
- Adjustable output
- Overcurrent protection
- High Operating temperature range 70deg C
- Input-Output isolation
- Suitable for a wide range of industrial applications
|
|
Input: |
12VDC (10.5-16V) |
|
24 VDC (20-30V) |
|
48 VDC (40-60V) |
Input protection: |
By external fuse |
efficiency: |
78-85% |
Voltage accuracy |
±2% |
Voltage adjustment |
±10% |
output protection |
Output current limiting witd auto recovery thermal shutdown
witd thermal start |
Line regulation |
±.04% |
Load regulation |
±.04% |
Operating temperature |
.-20C to 50 c @100% load |
|
+60C @ 75% load |
|
+70C @ 50% Load |
Dimensions: |
.APK25 &APK60: 110x65x13 |
Model |
input |
OutputV |
OutputA |
PowerW |
APK25-1205 |
12V |
5V |
5A |
25W |
APK25-1212 |
12V |
12V |
2A |
25W |
APK25-1215 |
12V |
15V |
1.6A |
25W |
APK25-1224 |
12V |
24V |
1.04A |
25W |
APK25-1248 |
12V |
48V |
0.52A |
25W |
APK25-2405 |
24V |
5V |
5A |
25W |
APK25-2412 |
24V |
12V |
2A |
25W |
APK25-2415 |
24V |
15V |
1.6A |
25W |
APK25-2424 |
24V |
24V |
1.04A |
25W |
APK25-2448 |
24V |
48V |
0.52A |
25W |
APK25-4805 |
48V |
5V |
5A |
25W |
APK25-4812 |
48V |
12V |
2A |
25W |
APK25-4815 |
48V |
15V |
1.6A |
25W |
APK25-4824 |
48V |
24V |
1.04A |
25W |
APK25-4848 |
48V |
48V |
0.52A |
25W |
|
|
|
|
|
APK60-1205 |
12V |
5V |
12A |
60W |
APK60-1212 |
12V |
12V |
5A |
60W |
APK60-1215 |
12V |
15V |
4A |
60W |
APK60-1224 |
12V |
24V |
2.5A |
60W |
APK60-1248 |
12V |
48V |
1.25A |
60W |
APK60-2405 |
24V |
5V |
12A |
60W |
APK60-2412 |
24V |
12V |
5A |
60W |
APK60-2415 |
24V |
15V |
4A |
60W |
APK60-2424 |
24V |
24V |
2.5A |
60W |
APK60-2448 |
24V |
48V |
1.25A |
60W |
APK60-4805 |
48V |
5V |
12A |
60W |
APK60-4812 |
48V |
12V |
5A |
60W |
APK60-4815 |
48V |
15V |
4A |
60W |
APK60-4824 |
48V |
24V |
2.5A |
60W |
APK60-4848 |
48V |
48V |
1.25A |
60W |
|